pH and Conductivity Meters: Benchtop, Portable or Multi-parameter?

How to choose a pH, conductivity or multi-parameter meter for water testing, with the HACH HQ series and sensION+ benchtop meters, calibration tips and probe care.

pH and conductivity are the two measurements most water laboratories make every day, so pH meters for water testing are usually the first lab pH instruments a laboratory buys. You can buy a single-parameter benchtop meter, a portable meter for field work, or a multi-parameter meter that covers several measurements with interchangeable probes. This guide helps you decide.

What each measurement tells you

  • pH shows how acidic or alkaline the water is. SANS 241 sets an operational limit of 5.0 to 9.7 at 25 °C.
  • Conductivity reflects dissolved salts. It is reported at 25 °C, so choose a meter with automatic temperature compensation.
  • TDS, dissolved oxygen, ORP and ion-selective measurements extend the same meter to more parameters when it takes more probe types.

The HACH range

Meter Measures Best for
sensION+ pH3 pH A benchtop laboratory with pH as the main test
sensION+ EC7 Conductivity A benchtop laboratory focused on conductivity
sensION+ MM374 pH, conductivity and ion-selective A laboratory that needs several measurements on one benchtop meter
HQ series pH, conductivity, TDS, dissolved oxygen, BOD, ORP and ISE with Intellical smart probes Laboratory and field use, portable and benchtop models

The HQ meters recognise each Intellical probe as you plug it in, so one meter covers several parameters with fewer operator errors.

Choosing

  • One parameter, one bench: a single-parameter benchtop meter is the simplest and usually the lowest cost.
  • Several parameters: a multi-parameter meter saves bench space and keeps the records in one place.
  • Field work, rounds or boreholes: a portable meter, ideally one with the same probes as your laboratory meter so results compare.

Calibration and probe care

Calibrate pH meters with two or three buffers that bracket your samples, and check the slope after each calibration. A slope of about 95 to 105 % is healthy. Store electrodes in storage solution, never in deionised water. Our pH meter calibration guide covers the steps. We stock buffers and probe maintenance solutions, and we calibrate meters; see our calibration service.

Browse the pH and conductivity pages for the full range, or tell us what you measure and we will recommend a meter.